Mastering the ANSI A117.1 Standard: A Complete Guide for Architects and Engineers

Learn how to apply ANSI/ICC A117.1 accessibility standards correctly, including door clearances, accessible routes, restrooms, path of travel upgrades, and Type A/B units. Understand jurisdictional amendments, ADA differences, and compliance strategies for new construction and alterations.
Arpit Jain
15 min
November 26, 2025

The ICC A117.1 standard, formally known as Accessible and Usable Buildings and Facilities, is the definitive technical guide for designing accessible spaces in the United States. While the Americans with Disabilities Act (ADA) establishes why accessibility is a civil right, the ANSI A117.1 standard provides the detailed, prescriptive requirements - the how - for everything from door clearances and restroom layouts to accessible routes and dwelling units.

For design professionals, understanding and correctly applying the specific edition of A117.1 adopted by your jurisdiction is non-negotiable. It is the primary standard referenced by the International Building Code (IBC) and is the basis for ensuring that buildings are safe and usable for people with physical disabilities.

This guide provides a comprehensive overview of the standard's most critical requirements, common points of confusion, and its relationship with other codes and laws.

  • What is ANSI A117.1? It is a technical standard, not a law, that provides detailed specifications for accessible design elements.
  • How is it enforced? It becomes mandatory when a state or local jurisdiction adopts a building code (like the IBC) that references it. The specific version in effect is the one cited by the adopted code, including any local amendments.

What's the difference between ANSI A117.1 and the ADA? The ADA is a federal civil rights law that prohibits discrimination based on disability. The 2010 ADA Standards for Accessible Design provide its technical requirements. ANSI A117.1 is a separate, voluntary consensus standard that building codes adopt. While they are very similar and extensively harmonized, the legally adopted building code (referencing A117.1) is what a building official enforces for a permit.

Document Type Enforcement Key Function
ADA Standards Federal Regulation Department of Justice (DOJ) Civil rights law establishing the minimum accessibility requirements nationwide.
IBC Model Building Code State/Local Jurisdiction Sets the scoping for what must be accessible (e.g., entrances, restrooms).
ICC/ANSI A117.1 Technical Standard Adopted by IBC Provides the technical criteria for how to make elements accessible (e.g., dimensions, slopes).

Why This Standard is So Complex

Navigating accessibility requirements is one of the most challenging aspects of code compliance. The rules are highly detailed, dimensional, and absolute - a quarter-inch can be the difference between a compliant design and a costly mistake. The complexity arises from the need to coordinate multiple overlapping requirements from building codes, federal laws like the ADA and Fair Housing Act (FHA), and local jurisdictional amendments that can modify the base rules.

This guide breaks down the most critical and frequently encountered sections of the ANSI A117.1 standard. We will cover the core principles and specific technical details that architects, engineers, and inspectors grapple with daily, from initial schematic design through final field inspections.

ANSI A117.1 vs. ADA: Determining Applicability, Code Versions, and Precedence

One of the most common sources of confusion for design professionals is the relationship between the ANSI A117.1 standard and the ADA Standards for Accessible Design. It's crucial to understand that they are separate documents with different legal standing. The ANSI A117.1 standard becomes legally enforceable when it is referenced by the building code adopted in your project's jurisdiction. The ADA is a federal law that applies independently.

The key to compliance is identifying which specific version of the A117.1 standard has been adopted. For example, a state may adopt the 2018 IBC, which references the 2009 edition of ICC A117.1. However, a city within that state might have a local amendment that explicitly requires compliance with the newer 2017 edition. In such cases, the local amendment takes precedence. When requirements between the adopted code and the ADA differ, the general rule is to follow the more stringent requirement to ensure compliance with both the building code and federal law.

  • Mandatory vs. Voluntary: ANSI A117.1 is only mandatory where adopted as part of the local building code. It generally does not apply to single-family home renovations unless they are funded by specific government programs
  • Which Version Applies? Always verify the adopted building code and any local amendments. Do not assume the latest version of A117.1 is in effect. The specific edition cited in the code is the one you must follow.
  • Key Definitions: Terms like "clear floor space" (the minimum unobstructed floor area required for a single stationary wheelchair, typically 30" x 48") and "reach ranges" are fundamental concepts defined with precise dimensions in the standard. The 2017 edition, for instance, specifies an unobstructed forward reach range of 15" minimum to 48" maximum high.

ANSI A117.1 vs. ADA: Determining Applicability, Code Versions, and Precedence

Accessible Door Design per ANSI A117.1: Clearances, Hardware, and Power Operators

Doors are one of the most critical elements of an accessible route, and their design is governed by highly specific rules in ANSI A117.1. Compliance involves much more than just the width of the door leaf. It includes the clear opening width, maneuvering clearances on both sides of the door, threshold heights, hardware type, and the force required to open it.

A common point of failure is the maneuvering clearance at the strike-side of the door. On the pull side of a forward-approached door, the standard requires a minimum of 18 inches of clear space adjacent to the strike-side jamb. This measurement is taken from the edge of the clear opening (the face of the door when open 90 degrees) to the nearest obstruction. This space is essential for a person in a wheelchair to be able to pull the door open while maneuvering out of its swing path.

  • Minimum Clear Width: The minimum clear opening width for a swinging door is 32 inches, measured from the face of the door (open 90 degrees) to the stop on the strike-side frame.
  • Hardware: Door hardware must be operable with one hand and not require tight grasping, pinching, or twisting of the wrist. This effectively prohibits traditional round doorknobs in accessible locations, favoring lever handles or push-type mechanisms instead.
  • Power Operators: Low-energy power-operated doors must adhere to strict timing and force requirements detailed in ANSI/BHMA A156.19, which is referenced by A117.1. For example, the door must take at least 3 seconds to move from the open position to a point 10 degrees from the latch. These parameters are verified during field inspections.
  • Secured Entrances: Devices like key card readers must be located on the accessible route and within the standard reach ranges (typically no higher than 48 inches). Their location must also be coordinated with the required door maneuvering clearances.

Accessible Door Design per ANSI A117.1: Clearances, Hardware, and Power Operators

Accessible Route Design Guide: Applying ANSI A117.1 for Ramps, Slopes, and Protruding Objects

An accessible route is a continuous, unobstructed path connecting all accessible elements and spaces of a building or site. ANSI A117.1 provides the technical criteria for every component of this route, including walking surfaces, ramps, curb ramps, and potential hazards like protruding objects.

Slope and cross-slope are fundamental to compliant design. The maximum running slope for a walkway to be considered part of an accessible route (and not a ramp) is 1:20 (5%). Anything steeper must be designed as a ramp with handrails, landings, and a maximum slope of 1:12 (8.33%). The maximum allowable cross-slope for any walking surface is 1:48 (2%). This is a critical detail, especially for exterior paths where proper drainage is also a concern.

  • Protruding Objects: An object mounted on a wall with its leading edge between 27 and 80 inches above the floor cannot project more than 4 inches into the circulation path. This rule is designed to protect individuals who are blind or have low vision. A common issue is a fire extinguisher cabinet; if the bottom edge of the cabinet is below 27 inches, it can be detected by a cane and is allowed to project more than 4 inches.
  • Thresholds: Thresholds at doorways cannot exceed 1/2 inch in height. Changes in level between 1/4 inch and 1/2 inch must be beveled with a slope no steeper than 1:2.
  • Ramp Flares: The flared sides of a curb ramp are permitted to have a slope up to 1:10 (10%), but only if they are not in a pedestrian circulation path. If the flares land in an area where people walk, their slope cannot exceed the 1:12 (8.33%) maximum of the ramp itself.
  • Vehicular Ways: Where an accessible route crosses a vehicular way (like a parking garage entrance), the walking surface must be clearly marked, and any slope transitions must meet the standards for walkways or ramps. Abrupt changes in level are not permitted.

Accessible Route Design Guide: Applying ANSI A117.1 for Ramps, Slopes, and Protruding Objects

Designing Compliant Accessible Restrooms: A Guide to ANSI A117.1 Clearances and Fixtures

Accessible restrooms are among the most scrutinized areas during plan review and inspection due to their complex dimensional requirements. A compliant design requires careful coordination of clear floor spaces, fixture locations, turning circles, and door swings.

A key requirement is the 60-inch diameter turning circle, which provides space for a wheelchair user to turn around. In a single-user restroom, the swing of the door is permitted to overlap this turning circle. However, in a multi-user restroom, the turning space must be kept clear of the swing of any stall door. Similarly, the required clear floor space at any individual fixture (e.g., a lavatory or urinal) cannot be obstructed by the swing of the main room door.

  • Clear Floor Space: The 30" x 48" clear floor space required at fixtures and the 60-inch turning circle are always measured from the face of finished surfaces (e.g., finished tile walls, not rough framing).
  • Toilet Height: The height of an accessible toilet seat, measured to the top of the seat, must be between 17 and 19 inches above the finished floor.
  • Grab Bars: Grab bars in toilet compartments and showers have precise mounting height ranges and locations relative to the fixture. For example, side wall grab bars in a toilet stall are typically mounted between 33 and 36 inches above the finished floor.
  • Unisex Restrooms: An accessible single-user or "unisex" restroom can be a valuable addition to a facility. However, whether it can count toward the total number of required fixtures depends on the specific scoping provisions of the adopted building code (IBC Chapter 11 and Chapter 29).

Designing Compliant Accessible Restrooms: A Guide to ANSI A117.1 Clearances and Fixtures

Type A & Type B Accessible Dwelling Units: A Guide to ICC A117.1 Requirements

In multi-family residential buildings (R-2 occupancies), the building code requires a certain percentage of dwelling units to be accessible. ANSI A117.1 defines two primary levels of accessibility for these units: Type A and Type B.

  • Type A Units: These units provide a higher level of accessibility, designed to be comparable to the standards for public accommodations. They require features like enhanced clearances in kitchens and bathrooms, and some elements that are adaptable (e.g., removable base cabinets at a sink). For example, a Type A kitchen may require both a forward and a parallel approach to appliances like a cooktop, significantly influencing the layout.
  • Type B Units: These units provide a baseline level of accessibility that aligns with the design and construction requirements of the Fair Housing Act (FHA). They are designed to be usable by a wider range of people and adaptable for greater accessibility in the future. Requirements include accessible routes into and through the unit, reachable light switches and outlets, and reinforced walls for the future installation of grab bars.

The interaction between A117.1 and the FHA is critical. The FHA has "safe harbor" provisions, meaning that designs compliant with certain technical standards, like specific editions of A117.1, are deemed to comply with the FHA's requirements. Designers must ensure they are following the correct standard referenced by the FHA or the locally adopted code to achieve full compliance. For elements like kitchen sinks, the standard requires that exposed pipes be configured to protect against contact, which can be achieved through insulation or protective panels.

Type A & Type B Accessible Dwelling Units: A Guide to ICC A117.1 Requirements

Applying ANSI A117.1 to Existing Buildings: Alterations, Path of Travel, and Technical Infeasibility

Applying accessibility standards to existing buildings presents unique challenges. The IBC and ANSI A117.1 contain specific provisions for alterations. When an element or space in an existing building is altered, the altered portion must be brought into compliance with the current code.

Furthermore, when a "primary function area" (e.g., the main office space in a commercial tenant improvement) is altered, there is an additional requirement to make the path of travel to that area accessible. This can include upgrading the building entrance, the route to the altered space, and any restrooms, phones, or drinking fountains serving it. However, the code places a limit on this expenditure: you are not required to spend more than 20% of the total cost of the alteration on these path-of-travel upgrades.

In some cases, especially in historic buildings or structures with physical constraints, achieving full compliance may be "technically infeasible." The code allows for specific exceptions when meeting a requirement would involve removing or altering a load-bearing member or creating an undue hardship. For example, if providing a 60-inch turning circle in an existing toilet room is technically infeasible, the standard permits an alternative T-shaped turning space. Justifying this requires clear documentation to be submitted to the building official for approval.

Applying ANSI A117.1 to Existing Buildings: Alterations, Path of Travel, and Technical Infeasibility

Specialized Accessibility Requirements in ANSI A117.1: Signage, Seating, Areas of Refuge, and Pools

Beyond the common requirements for routes, doors, and restrooms, ANSI A117.1 contains detailed criteria for a wide range of specialized building elements. These requirements often need to be coordinated with other sections of the building code.

  • Signage: The standard includes precise specifications for tactile signs (with raised characters and Braille), including character height, stroke width, font type, and mounting location. These requirements are closely harmonized with the ADA Standards.
  • Assembly Seating: In venues like theaters and stadiums, wheelchair-accessible seating must be provided. The rules require these spaces to be dispersed throughout the venue to provide a variety of sightlines and ticket price points comparable to those offered to the general public.
  • Areas of Refuge: An area of refuge is a space within a multi-story building where occupants unable to use stairs can await assistance during an emergency. ANSI A117.1 specifies the minimum size for a wheelchair space within this area (typically 30" x 48"), which must be located outside of required egress widths. These requirements must be coordinated with egress calculations from IBC Chapter 10 and two-way communication system requirements.
  • Swimming Pools: For public pools, accessibility can be provided via a sloped entry or a pool lift. A117.1 provides the technical specifications for lifts, including seat size, lifting capacity, and the clear deck space required for maneuvering a wheelchair into position.

Specialized Accessibility Requirements in ANSI A117.1: Signage, Seating, Areas of Refuge, and Pools

Navigating Permitting and Plan Review

Submitting a project for permit requires clear and comprehensive documentation of accessibility compliance. Plan reviewers are trained to look for common errors, and missing or incorrect information is a frequent cause of permit delays.

Best Practices for Documentation:

  • Show All Clearances: On your floor plans, graphically indicate all required maneuvering clearances at doors, clear floor spaces at fixtures, and turning circles. Do not make the reviewer guess or scale the drawing.
  • Detail Sheets: Create dedicated accessibility detail sheets that show mounting heights for all accessories (grab bars, dispensers, mirrors), fixture elevations, and signage requirements.
  • Specify the Correct Code: Your code analysis sheet should clearly state the edition of the IBC and the referenced ANSI A117.1 standard that your project is designed to meet.
  • Technical Infeasibility: If you are claiming technical infeasibility for an element in an alteration, provide a separate narrative and supporting drawings that clearly explain the structural or physical constraint and show your proposed alternative solution.

How Different Codes and Standards Interact

Successful accessibility design requires understanding how multiple documents work together. No single code or standard exists in a vacuum.

Code/Standard Role in Accessibility How it Interacts
International Building Code (IBC) Provides the "scoping" requirements - what, where, and how many accessible features are required. References ANSI A117.1 for all the technical "how-to" details (e.g., dimensions, slopes).
ICC/ANSI A117.1 Provides the detailed technical criteria for how to design accessible elements The "dictionary" of accessible design referenced by the IBC. It does not determine where features are required.
2010 ADA Standards Federal law that provides both scoping and technical rules. Applies independently of the building code. Heavily harmonized with IBC/A117.1. Where differences exist, the more stringent requirement should be followed.
Fair Housing Act (FHA) Federal law requiring specific accessibility features in multi-family housing. Establishes requirements for Type B units. ANSI A117.1 is a "safe harbor" standard for FHA compliance.
Local Amendments Modifications to the model code adopted by a city, county, or state. Can change the adopted version of A117.1, add new requirements, or modify existing ones. Always takes precedence.

The Critical Impact of Jurisdictional Amendments

Never assume the model IBC or the latest version of ANSI A117.1 is what applies to your project. Building codes are adopted and enforced at the state and local levels, and amendments are common.

Why checking amendments is crucial:

  • Different Versions: A city may be on a newer or older version of the A117.1 standard than the state.
  • Stricter Requirements: Some jurisdictions, like California with its CBC, have accessibility requirements that are significantly more stringent or detailed than the model codes.
  • Unique Local Rules: A city might have a specific ordinance regarding unisex toilet rooms or path-of-travel upgrade thresholds that differs from the IBC.

Before beginning any project, your first step should be to contact the local building department or check their website to confirm the exact codes, standards, and amendments that are currently in effect. This single step can save you countless hours of redesign and prevent costly construction changes.

Frequently Asked Questions

What's the difference between "ICC A117.1" and "ANSI A117.1"?

They are the same standard. ANSI (American National Standards Institute) is the organization that oversees the development and approval process for standards. The ICC (International Code Council) is the secretariat that develops and publishes this specific standard. You will see both names used, but they refer to the same document.

Does compliance with the IBC and ANSI A117.1 guarantee compliance with the ADA?

In most cases, yes. The IBC and A117.1 have been extensively harmonized with the 2010 ADA Standards. The IBC explicitly states that buildings designed and constructed in accordance with its accessibility provisions are "deemed to comply" with the ADA's design requirements. However, the ADA covers more than just building design (e.g., policies and procedures), and ultimate enforcement is up to the Department of Justice. Following the adopted code is your primary obligation for permitting, but it's wise to be aware of any minor differences.

How often is the ANSI A117.1 standard updated?

The standard is typically updated on a cycle of roughly 5-8 years. Recent major editions include 2003, 2009, and 2017. However, the adoption of these new editions by local jurisdictions can lag by several years.

Can I use a newer version of A117.1 if my jurisdiction has adopted an older one?

You must design to the standard that is legally adopted by the jurisdiction. While a newer standard may offer improved guidance, the building official can only enforce the code that is law in their city or state. If you wish to use a provision from a newer standard, you would need to present it as an "alternative means and methods" and get explicit approval from the plan reviewer.

What are the most common accessibility mistakes found during site inspections?

Common field inspection failures include incorrect door maneuvering clearances (especially strike-side), improper grab bar locations, restroom accessories mounted outside of reach ranges, and incorrect slopes on exterior walkways and ramps that are off by even a small percentage.

How does the Fair Housing Act (FHA) relate to ANSI A117.1 Type B units?

The FHA requires seven basic design features for accessibility in covered multi-family housing. The technical requirements for Type B units in ANSI A117.1 are designed to meet or exceed these FHA requirements. Complying with the A117.1 Type B provisions is considered a "safe harbor," meaning it is one way to demonstrate compliance with the FHA's design and construction rules.

References

  1. American National Standard – ICC A117.1 (2017) – official preview/documentation page for the 2017 edition of the standard: https://codes.iccsafe.org/content/icca117-12017/american-national-standard 
  2. Chapter 4 – Accessible Routes” from ICC A117.1-2017 – which covers slope, cross-slope, clear widths, and accessible route components. https://codes.iccsafe.org/content/icca117-12017/chapter-4-accessible-routes 
  3. ANSI Blog: “ICC/ANSI A117.1-2017: Accessible & Usable Buildings and Facilities” – overview of major changes and how the standard fits into the accessibility ecosystem. https://blog.ansi.org/ansi/icc-ansi-a117-1-2017-accessible-buildings 
  4. Supplement 1 to A117.1 — 2017 Edition” – details on the 2024 approved supplement adding adult changing station requirements (Section 613) to the 2017 edition: https://codes.iccsafe.org/content/IBCACCPB2024P1/supplement-1-to-a117-1-2017-edition 
  5. ICC/ANSI A117.1 and the Top 20 Frequently Asked Questions” – a practical reference by a state government agency clarifying how A117.1 is applied (e.g., relation with the model code) https://portal.ct.gov/das/-/media/das/oedm/2017-cd-ho/fall-2017iccansi-a1171-and-top20questionsrevised-091520172-slide-handouts.pdf

AI assistant for code research & compliance

AI-powered Takeoff Service

Follow us

This content is for informational purposes only, based on publicly available sources. It is not official guidance. For any building or compliance decisions, consult the appropriate authorities or licensed professionals.

Your AI-assistant for code research

AI-powered Takeoff Service

Interface with dropdown menus for selecting code categories, jurisdiction, and year above a search bar containing a fire safety question about non-sprinklered Group I-2 occupancy with a laundry room over 100 square feet.List of features with check marks: 2D / 3D / Conceptual, Upfront Pricing, Fast & Guaranteed Turnaround Time, Estimators with 15+ year experience.