Building Types

Restaurant and Food Service Design

Designing the dining room and the commercial kitchen as one working system.

Quick Answer

Restaurant and food service design plans both the guest-facing dining areas, called front of house, and the commercial kitchen, receiving, storage, and staff areas, called back of house. The design must support workflow, health department requirements, ventilation and grease exhaust, plumbing, fire protection, and accessible seating.

The Full Picture

A restaurant is two buildings working as one. Front of house includes the entry, host stand, dining room, bar, restrooms, and sometimes patios. Back of house includes the kitchen, dish area, walk-in coolers and freezers, dry storage, receiving, offices, and staff spaces. The way these zones connect decides how fast food reaches tables and how efficiently staff work.

The kitchen is the technically demanding part. Cooking equipment under hoods needs exhaust and makeup air, and grease-producing appliances typically require grease duct systems and fire suppression designed to standards such as NFPA 96. Floor drains, grease interceptors, hot water, gas service, refrigeration, and electrical capacity add up to a heavy mechanical, electrical, and plumbing load for the floor area.

Food service facilities are also regulated by local health departments, which usually review plans before construction and inspect before opening. Requirements commonly cover finishes, handwashing sinks, storage, and equipment layout, and they vary by jurisdiction. Accessibility rules apply to dining areas, counters, and restrooms, and occupancy and egress depend on seating counts.

For a general contractor, restaurants are fit-out projects where kitchen equipment is often supplied by the owner or a food service equipment dealer and installed or connected by the contractor. Coordination of equipment cut sheets, rough-in locations, hood and exhaust routing, and utility capacity is where many scope gaps and change orders arise, and equipment lead times can drive the schedule.

Real Examples

→Casual dining tenant: A restaurant leases a second-generation space. The team finds the existing roof cannot carry the new exhaust fan and makeup air unit without structural reinforcement, which changes the budget.
→Ghost kitchen: A delivery-only kitchen has no dining room, so front of house shrinks to a pickup area and nearly all the budget goes to cooking equipment, exhaust, refrigeration, and utilities.
→Equipment rough-in: The kitchen equipment package arrives after the plumbing rough-in. A mismatch in drain locations means opening finished slab areas, so the contractor asks for equipment cut sheets early.

Common Misconceptions

People assume: Restaurant construction is like any other interior build-out.

Actually: Exhaust, grease, gas, refrigeration, plumbing, and health department review make restaurants far more systems-heavy than typical tenant spaces.

People assume: The kitchen equipment is simply plugged in at the end.

Actually: Equipment requires coordinated rough-ins for utilities, drains, and exhaust well before finishes, and late or changed equipment selections commonly cause rework.

Frequently Asked Questions

What does FOH and BOH mean?

FOH is front of house, the guest-facing areas such as the dining room and bar. BOH is back of house, the kitchen, storage, receiving, and staff areas guests do not see.

Why do commercial kitchens need special exhaust?

Cooking produces heat, smoke, and grease vapor. Hoods and exhaust systems remove them, and grease-laden systems typically follow fire safety standards such as NFPA 96.

What is a grease interceptor?

It is a plumbing device that separates fats, oils, and grease from kitchen wastewater before it reaches the sewer. Whether one is required and what size depends on local plumbing and utility rules.

Who reviews restaurant plans?

Along with the building department, the local health department usually reviews food service plans. Requirements and review procedures differ by jurisdiction.

What drives restaurant construction schedules?

Permitting, health department review, and long-lead kitchen equipment and hood systems are common drivers, along with landlord approvals in leased spaces.

Related Terms

More Building Types Terms

Sources

  1. NFPA 96 — Ventilation Control and Fire Protection of Commercial Cooking Operations
  2. U.S. Department of Justice — ADA Design Standards
  3. Whole Building Design Guide (WBDG) — Building Types
  4. International Code Council — Model Codes and Standards