Electrical Conduit

The tube that protects and routes electrical wiring through a building.

Quick Answer

Electrical conduit is a tube, metal or plastic, that holds and protects electrical conductors and is one kind of raceway. Common types are EMT, rigid metal conduit and PVC. It is taken off in linear feet by type and trade size, with fittings, supports and boxes counted separately.

The Full Picture

Conduit is a raceway, which OSHA defines as an enclosed channel designed expressly for holding wires, cables or busbars. The type chosen depends on where it runs. EMT, electrical metallic tubing, is the thin-wall metal tube common indoors. Rigid metal conduit is heavier and used where more physical protection is needed. PVC is nonmetallic and is typically used underground or embedded in concrete. Flexible and liquidtight types connect to motors and vibrating equipment. Which type goes where is set by the spec and the code.

Conduit appears on the plans in several ways. Power and lighting plans show it as line work with hash marks, home runs and circuit numbers. Underground and site plans show duct banks and routing. Riser diagrams show vertical feeder conduit between floors. The spec section for raceways sets the permitted types by location, minimum sizes and any color or separation rules. Conduit sizing for a feeder or large run often comes from a schedule in the drawings, not from the plan lines.

The takeoff unit is the linear foot, sorted by type and trade size, since a 1/2 in and a 2 in run are priced very differently. Fittings are counted EA: couplings, connectors, elbows where factory bends are used, boxes and bodies. Supports are counted per spacing, and the estimator rounds up. Stick length matters for ordering: EMT is commonly sold in 10 ft lengths, so a run is rounded up to whole sticks. Waste and offsets are an assumption each estimator sets.

Conduit is where underestimates hide. Long vertical runs, offsets around beams, routing that follows walls instead of straight lines, pull boxes on long or bend-heavy runs, and sleeves and firestopping at wall and floor penetrations are all easy to leave out. Check the wiring methods in the spec against the plan too: pricing EMT where the spec calls for rigid, or leaving out seals and expansion fittings, changes the line.

Real Examples

→Worked takeoff: one run of 3/4 in EMT: A feeder run of 3/4 in EMT measures 60 LF. At 10 ft per stick, that is 60 / 10 = 6 sticks. Joining 6 sticks takes 6 - 1 = 5 couplings, plus 2 connectors at the boxes. At supports every 8 ft (an assumed spacing), 60 / 8 = 7.5, rounded up to 8 straps. The estimator adds the offsets and bends shown at beams on top of this.
→Underground branch: A site plan shows 140 LF of PVC from a pole base to the building, with 2 elbows turning up at each end. The estimator takes the run in LF, counts 4 elbows EA, and adds trench and backfill from the site takeoff, since those are in different trades' scope.
→Type conflict: The plan shows a conduit run to a rooftop unit, and the spec requires liquidtight flexible conduit for the last connection to equipment. The estimator adds a short flexible section and its fittings at each unit.

Common Misconceptions

People assume: All conduit is priced the same per foot.

Actually: Price varies widely by type and trade size. Rigid metal, EMT and PVC are different materials with different fittings and labor, so each type and size is its own line.

People assume: A conduit takeoff only needs the straight-line length.

Actually: The plan length omits vertical rises, offsets, bends, pull boxes and wall and floor penetrations. Those are counted separately or added as allowances.

Does MeltPlan Solve This?

Partially — adjacent

Conduit routes and lengths are measured from electrical plans, and MeltPlan's takeoff service covers that measuring: AI pulls quantities from the plans, and US-based experienced estimators review and adjust them. The choice of conduit type, the routing judgment and the waste and labor assumptions stay with your estimator.

Get conduit lengths measured from your electrical plans →

Frequently Asked Questions

What are the main types of electrical conduit?

The common types are EMT, rigid metal conduit, PVC and flexible or liquidtight conduit. They differ in wall thickness, material and where they are permitted, which the spec and local code decide.

How is conduit measured in a takeoff?

Conduit is taken off in linear feet by type and trade size. Couplings, connectors, elbows, boxes and supports are counted EA, and the total is usually rounded up to whole sticks.

Is conduit the same as a raceway?

Conduit is one kind of raceway. A raceway is any enclosed channel for wires, cables or busbars, which also includes cable tray, wireways and surface raceway.

What is the difference between EMT and rigid conduit?

EMT is a thinner-wall tube with simple fittings, while rigid conduit has a heavier wall and threaded fittings. The spec sets which may be used in a given location.

Related Terms

More Takeoff & Estimating — Electrical & Low-Voltage Terms

Sources

  1. 29 CFR 1910.399: Definitions applicable to electrical installations (Cornell LII)
  2. 29 CFR 1910.305: Wiring methods, components and equipment (Cornell LII)
  3. NFPA 70: National Electrical Code

Automate quantity takeoffs with AI

Fill in the details and our team will reach out.

Contact us today

Automate quantity takeoffs with AI

MELTPLAN